8-Port Ethernet Remote I/O Networking Modbus/TCP Module - CIE-M10

8-Port Ethernet Remote I/O Networking Modbus/TCP Module - CIE-M10

  • Product SKU: SOL-CIE-M10
Available: In Stock
Wishlist

8-Port Ethernet Remote I/O Networking Modbus/TCP Module - CIE-M10

CIE-M10 is an Ethernet remote I/O module that has 8 input ports, 8 output ports and an ADC (Analog to Digital Conversion) port for sensors to detect temperature, humidity or pressure. This remote I/O module is additionally equipped with a UART interface to allow your serial devices to establish an Ethernet networking connection. CIE-M10 mainly enables you to extend the distance of the I/O control system, therefore you are able to remotely control and monitor your I/O devices over the Internet from anywhere in the world.

As well as with a simple management tool (ModMap), this Ethernet remote I/O module comes preloaded with a user web page, which is available to customize with your own graphic images, to ease control and surveillance on the website. Besides, a Macro function allows each relay output to be automatically controlled as set by simple logic formula.

Since this Ethernet remote I/O module has various methods to control outputs and monitor inputs such as HTTP, Modbus/TCP and Serialized Modbus/TCP, it is available on various environments such as Internet Switch, etc.

 

Features:

  • Compact size
  • 8 x digital input port
  • 8 x digital output port (3.3V CMOS)
  • 1 x ADC
  • Modbus/TCP
  • Controlled by simple logic formula operating autonomously
  • Web-based control over custom web page
  • Used as Internet Switch
  • Free mobile application

Specifications:

Digital Input Port
Number of Ports 8
Interface 3.3V CMOS
Electric Parameter Min VIL=-0.3V, Max VIL=0.8V
Min VIH=2.0V, Max VIH=5.5V
Digital Output Port
Number of Ports 8
Interface 3.3V CMOS
Relay Capacity Min VOH=2.9V, Max VOL=0.4V
Analog Input Port
Number 10bit ADC 1 Port
Interface ADIN, ADVREF
Conversion Time 2.33us
Electric Parameter Min ADVREF=2.6V, Max ADVREF=3.3V
ADIN's Input Voltage Range = 0V ~ VADVREF
Serial Physical Interface
Serial Interface 1 x UART Port/RXD, TXD, RTS, CTS, GND
Electric Parameter Min VIL = -0.3V, Max VIL = 0.8V
Min VIH=2.0V, Max VIH=5.5V
Min VOH=2.9V, Max VOL=0.4V
Serial Port Property
Baudrate 300bps~230,400bps
Data Bits 5, 6, 7, 8 bits
Parity None, Even, Odd, Mark, Space
Stop Bits 1, 1.5, 2
Network Physical Interface
Network Interface 10Base-T/100Base-TX Ethernet (RJ45)
Ethernet Speed Auto Sense
1:1 or Cross-over Cable Auto Sense
1000 VAC Isolation
Software Functions
Protocols TCP, UDP, IP, ICMP, ARP, Ethernet, TELNET
TFTP DHCP, PPPoE, DNS, DDNS, HTTP, Modbus/TCP
Security IP & MAC filtering - Restrict host or network
Password for Configuring
Digital I/O Port
Communication Mode
Modbus/TCP, HTTP (User web page)
Stand alone (by simple equation)
Serial Port
Communication Mode
TCP Server (T2S)
TCP Client (COD)
TCP Server/Client with AT command (ATC)-Patent
UDP Mode (U2S)
Additional Functions Remote Debug Function
TCP Server/Client mode
Sending MAC address Option
Indicators (LEDs)
Power Red
Digital Output Port 0 Green
Management
ezManaver Configuration and Monitoring Tool through Ethernet
Telnet Telnet Login
AT Command Configuring in ATC mode-Patent
Supplementary Software
ezManager Configuration Tool for Windows
ModMap Management Tool of I/O controllers for Windows
ezVSP Serial to Network Virtual Driver for Windows
ezTerm Simple TCP/IP Communication Test Tool
Dimension
Size 64.4mm x 40mm x 17mm
Operating Environment
Input Voltage DC 3.3V±0.3V
Power Consumption 190mA @ 3.3V without load
Operating Temperature 0℃ ~ +70℃
Storage Temperature -40℃ ~ +85℃

 

Product Documentation LINK Here -->

 

 

 

8-Port Ethernet Remote I/O Networking Modbus/TCP Module - CIE-M10

CIE-M10 is an Ethernet remote I/O module that has 8 input ports, 8 output ports and an ADC (Analog to Digital Conversion) port for sensors to detect temperature, humidity or pressure. This remote I/O module is additionally equipped with a UART interface to allow your serial devices to establish an Ethernet networking connection. CIE-M10 mainly enables you to extend the distance of the I/O control system, therefore you are able to remotely control and monitor your I/O devices over the Internet from anywhere in the world.

As well as with a simple management tool (ModMap), this Ethernet remote I/O module comes preloaded with a user web page, which is available to customize with your own graphic images, to ease control and surveillance on the website. Besides, a Macro function allows each relay output to be automatically controlled as set by simple logic formula.

Since this Ethernet remote I/O module has various methods to control outputs and monitor inputs such as HTTP, Modbus/TCP and Serialized Modbus/TCP, it is available on various environments such as Internet Switch, etc.

Learn more about remote digital I/O control solution  >  

 

Features:

  • Compact size
  • 8 x digital input port
  • 8 x digital output port (3.3V CMOS)
  • 1 x ADC
  • Modbus/TCP
  • Controlled by simple logic formula operating autonomously
  • Web-based control over custom web page
  • Used as Internet Switch
  • Free mobile application

Specifications:

Digital Input Port
Number of Ports 8
Interface 3.3V CMOS
Electric Parameter Min VIL=-0.3V, Max VIL=0.8V
Min VIH=2.0V, Max VIH=5.5V
Digital Output Port
Number of Ports 8
Interface 3.3V CMOS
Relay Capacity Min VOH=2.9V, Max VOL=0.4V
Analog Input Port
Number 10bit ADC 1 Port
Interface ADIN, ADVREF
Conversion Time 2.33us
Electric Parameter Min ADVREF=2.6V, Max ADVREF=3.3V
ADIN's Input Voltage Range = 0V ~ VADVREF
Serial Physical Interface
Serial Interface 1 x UART Port/RXD, TXD, RTS, CTS, GND
Electric Parameter Min VIL = -0.3V, Max VIL = 0.8V
Min VIH=2.0V, Max VIH=5.5V
Min VOH=2.9V, Max VOL=0.4V
Serial Port Property
Baudrate 300bps~230,400bps
Data Bits 5, 6, 7, 8 bits
Parity None, Even, Odd, Mark, Space
Stop Bits 1, 1.5, 2
Network Physical Interface
Network Interface 10Base-T/100Base-TX Ethernet (RJ45)
Ethernet Speed Auto Sense
1:1 or Cross-over Cable Auto Sense
1000 VAC Isolation
Software Functions
Protocols TCP, UDP, IP, ICMP, ARP, Ethernet, TELNET
TFTP DHCP, PPPoE, DNS, DDNS, HTTP, Modbus/TCP
Security IP & MAC filtering - Restrict host or network
Password for Configuring
Digital I/O Port
Communication Mode
Modbus/TCP, HTTP (User web page)
Stand alone (by simple equation)
Serial Port
Communication Mode
TCP Server (T2S)
TCP Client (COD)
TCP Server/Client with AT command (ATC)-Patent
UDP Mode (U2S)
Additional Functions Remote Debug Function
TCP Server/Client mode
Sending MAC address Option
Indicators (LEDs)
Power Red
Digital Output Port 0 Green
Management
ezManaver Configuration and Monitoring Tool through Ethernet
Telnet Telnet Login
AT Command Configuring in ATC mode-Patent
Supplementary Software
ezManager Configuration Tool for Windows
ModMap Management Tool of I/O controllers for Windows
ezVSP Serial to Network Virtual Driver for Windows
ezTerm Simple TCP/IP Communication Test Tool
Dimension
Size 64.4mm x 40mm x 17mm
Operating Environment
Input Voltage DC 3.3V±0.3V
Power Consumption 190mA @ 3.3V without load
Operating Temperature 0℃ ~ +70℃
Storage Temperature -40℃ ~ +85℃

 

Product Documentation LINK Here -->